Parameter | Unit | 1*2 | 1*4 | 1*8 | 1*16 | 1*32 | 1*64 | |||
Insertion loss at 23°C | type | dB | 3.6 | 6.8 | 10 | 13 | 16 | 19.5 | ||
(P/S) max | 3.8/4.0 | 7.1/7.3 | 10.2/10.5 | 13.5/13.7 | 16.5/16.8 | 20.5/21.0 | ||||
Channel uniformity | typical | dB | 0.4 | 0.5 | 0.5 | 1.0 | 1.0 | 2.5 | ||
max | 0.6 | 0.6 | 0.8 | 1.2 | 1.5 | 2.5 | ||||
PDL | type | dB | 0.1 | 0.1 | 0.1 | 0.2 | 0.2 | 0.2 | ||
maximum | dB | 0.15 | 0.15 | 0.25 | 0.3 | 0.3 | 0.3 | |||
Wavelength department loss (dB) | typical | dB | 0.1 | 0.1 | 0.1 | 0.1 | 0.2 | 0.2 | ||
max | dB | 0.2 | 0.2 | 0.3 | 0.5 | 0.5 | 0.5 | |||
Temperature department loss (dB) | typical | 0.3 | 0.3 | 0.3 | 0.4 | 0.4 | 0.4 | |||
max | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | ||||
Directivity (dB) min | 55 | |||||||||
Return loss (dB) min | 55(50) | |||||||||
Operation temperature | °C | -40 to +85 | ||||||||
Storage temperature | °C | -40 to +85 | ||||||||
Fiber type | - | ITU G652.D/G657.A |